Технические данные PDF

Краткое описание: технические характеристики  UC6000-FP-E6-R2-P5

Описание оборудования
Single head system
General specifications
Sensing range800 ... 6000 mm
Dead band0 ... 800 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox. 65 kHz
Response delayfor factory setting
minimal (EM; NONE): ≤180 ms (2 measuring cycles)
default (EM, MXN, 5, 2): ≤360 ms (4 measuring cycles)
dynamic (EM, DYN): ≤270 ms (3 measuring cycles)
Indicators/operating means
LED yellowswitching state switch output 1
switching state switch output 2
LED red/greensolid green : "Power on", flashes during standby operation
red flashing : "Error", (e. g. background noise level too high)
Electrical specifications
Operating voltage15 ... 30 V DC , ripple 10 %SS
No-load supply current≤ 60 mA
Interface
Interface typeRS 232, 9600 bit/s, no parity, 8 data bits, 1 stop bit
Input/Output
Synchronization1 synchronous connection, bidirectional
0-level: -UB ... (-UB + 1 V), 1-level: (-UB + 5 V) ... +UB
Pulse length≥ 100 µs
Pause length≥ 2 ms
Synchronization frequency≤ 10 Hz , with external synchronization
Output
Output type2 switch outputs PNP, NO/NC
Rated operating current200 mA , short-circuit/overload protected
Voltage drop≤ 3 V DC
Resolution< 1 mm
Repeat accuracy≤ 0.1 % of full-scale value
Range hysteresis≤ 1 % of the set operating distance
Temperature influence≤ 2 %
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP65
Connectionterminal compartment, ≤ 2.5 mm2 conductor csa
Material
HousingPBT
Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam
Mass320 g