Технические данные PDF

Краткое описание: технические характеристики  IQT1-18GM-R4-V1

Описание оборудования
HF R/W system, ISO 15693
General specifications
Operating frequency13.56 MHz
Transfer rate26 kBit/s
Sensing range
Read distance0 ... 50 mm
Write distance0 ... 50 mm
Widthmax. 45 mm
UL File NumberE87056
Functional safety related parameters
MTTFd750 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED green/yellowMultihole-LED:
green: power on
green flashing: read/write attempt performed
yellow: data carrier detected
Electrical specifications
Rated operating voltage10 ... 30 V DC , ripple 10 %SS , limited power source (EN 60950)
Power consumption≤ 1.2 W
Interface
Physical RS-485 point-to-point connection
ProtocolASCII
Transfer rate1200, 2400, 4800, 9600, 19200, 38400 (default) Bit/s
Cable length≤ 3 m
Directive conformity
Radio equipment
Directive 2014/53/EUEN 301489-1
EN 301489-3
EN 300330
EN 62368-1
EN 50364
RoHS
Directive 2011/65/EU (RoHS)EN 50581
Standard conformity
Degree of protectionEN 60529
RFIDISO/IEC 15693-2
ISO/IEC 15693-3
ISO/IEC 18000-3
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingPBT/stainless steel
Encapsulation compoundCY 221/HY 2966
Installationnon-flush
Distance between two heads≥ 80 mm
Massapprox. 40 g
Оформить заказ на IQT1-18GM-R4-V1 вы можете в компании compeq-pepperl отправив заявку по почте, а также по телефону или в офисе компании.