Технические данные PDF

Краткое описание: технические характеристики  PHA200-F200-R2

Описание оборудования
Precision positioning on hole in the 70 mm x 70 mm housing
General specifications
Light sourceLED
Light typeIntegrated LED lightning (infrared)
Read distance200 mm
Capture rangemax. 120 mm x 100 mm
Functional safety related parameters
MTTFd70 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Function indicator4 x LED yellow: +X, -X, +Y, -Y
Control elementsnone
Electrical specifications
Operating voltage24 V DC ± 15% , PELV
Interface
Interface typeserial , RS 232
Input
Switching thresholdlow: < 10 V, high: > 15 V
Output
Switching typePNP , short-circuit/overload protected
Signal output+X, -X, +Y, -Y
Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/ECEN 61326-1 , EN 61000-6-4
Standard conformity
Noise immunityEN 61326-1:2006
Emitted interferenceEN 61000-6-4:2007/A1:2011
Approvals and certificates
CCC approvalCCC approval / marking not required for products rated ≤36 V
ApprovalsCE
Mechanical specifications
Degree of protectionIP67
Connection8-pin, M12x1 connector, standard (supply+IO) ,
5-pin, M12x1 socket, standard (RS 232) ,
4-pin, M12x1 socket, standard (LAN)
Material
Optical facePlastic pane