Технические данные PDF

Краткое описание: технические характеристики  VAA-2E1A-G10-SAJ/EA2J-2X1M

Описание оборудования
G10 safety module
2 safety inputs and
1 standard electronic output
General specifications
Slave typeSafety-Slave
AS-Interface specificationV3.0
Required master specification≥ V2.1
UL File NumberE223772 "For use in NFPA 79 Applications only"
Indicators/operating means
LED FLTerror display; LED red
red: communication error or address is 0
LED AS-iAS-Interface voltage; green LED
green: voltage OK
flashing green: address 0
LED INswitching state (input); 2 LED yellow
LED OUTSwitching state (output); LED yellow
Electrical specifications
Rated operating voltage26.5 ... 31.6 V from AS-Interface (PELV)
Rated operating current≤ 90 mA
Protection classIII
Surge protectionovervoltage category III
Rated insulation voltage32 V
Pulse withstand voltage0.8 kV
Input
Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored:
2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or
1 2-channel contact: up to category 4/PL e to ISO 13849-1
Supplyfrom AS-Interface
Voltage20 ... 30 V DC pulsed
Currentinput current limited ≤ 15 mA,
short-circuit protected
Output
Number/Type1 conventional electronic output, PNP
Supplyfrom AS-Interface
Voltage(UASI - 7.0 V) ≤ UOUT ≤ UASI
Current50 mA , short-circuit/overload protected
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007
Machinery Directive
Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
Electrical safetyIEC 61140:2009
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityIEC 62026-2:2013 EN 62061:2005 EN 61000-6-2:2005
Functional safetyEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Programming instructions
ProfileS-7.B
IO code7
ID codeB
ID1 codeF
ID2 code0
Data bits (function via AS-Interface) input output
D0 dyn. safety code 1 OUT 1
D1 dyn. safety code 1 -
D2 dyn. safety code 2 -
D3 dyn. safety code 2 -
Parameter bits (programmable via AS-i)function
P0communication monitoring
P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1not used
P2not used
P3not used
Approvals and certificates
UL approvalcULus Listed, Type 1 enclosure
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-25 ... 80 °C (-13 ... 176 °F)
Relative humidity< 95 %
Altitude≤ 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks
10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree3
Mechanical specifications
Degree of protectionIP67
This protection class is achieved by using the AS-Interface flat cable VAZ-FK-S-YE
ConnectionAS-Interface: AS-Interface flat cable
Inputs/outputs: open conductor ends
Material
Contactsopen conductor ends with connector sleeves
HousingPBT
CablePUR
Mounting screwStainless steel 1.4305 / AISI 303
Cable
Sheath diameter∅4,3 mm
Bending radius> 5 x cable diameter, fixed > 10 x cable diameter, moving not appropriate for conveyor chains
Colorblack
Cores4 x 0.34 mm2
Length1 m
Mass200 g
Tightening torque, fastening screws1.65 Nm
Оформить заказ на VAA-2E1A-G10-SAJ/EA2J-2X1M вы можете в компании compeq-pepperl отправив заявку по почте, а также по телефону или в офисе компании.