NJ15-30GM50-E2-V1-3G- xx3Gxx3D
Артикул: 129851
Inductive sensor
7 772 Р
Производитель:
PEPPERL+FUCHS
Поделиться:
Производитель: PEPPERL+FUCHS
(!) Производство этого продукта прекращено, изделие имеет замену. Перейти к странице изделия-замены. NJ15-30GM50-E2-V1-3G-3D
Краткое описание: технические характеристики NJ15-30GM50-E2-V1-3G- xx3Gxx3D
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 15 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 12.15 mm | |
Actual operating distance | 9 ... 11 mm typ. 10 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.38 | |
Reduction factor r304 | 0.71 | |
Reduction factor rBrass | 0.45 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 60 V DC | |
Switching frequency | 0 ... 500 Hz | |
Hysteresis | 1 ... 15 typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | ≤ 2.8 V | |
Voltage drop at IL | ||
Voltage drop IL = 10 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V | |
Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V | |
Voltage drop IL = 50 mA, switching element on | 0.9 ... 2.5 V typ. 1.7 V | |
Voltage drop IL = 100 mA, switching element on | 1 ... 2.6 V typ. 1.8 V | |
Voltage drop IL = 200 mA, switching element on | 1.2 ... 2.8 V typ. 2 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.01 mA | |
No-load supply current | ≤ 9 mA | |
Time delay before availability | ≤ 50 ms | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1184 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
|
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector plug M12 x 1 , 4-pin | |
Core cross-section | - | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP67 | |
Equipment protection level Gc (nA) | ||
CE marking | [*PD-Z02586A*] | |
Special conditions | ||
Maximum operating current IL | The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. | |
Maximum operating voltage UBmax | The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible. | |
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. |
|
at UBmax=60 V, IL=200 mA | 50 °C (122 °F) | |
at UBmax=60 V, IL=100 mA | 54 °C (129.2 °F) | |
at UBmax=30 V, IL=200 mA | 54 °C (129.2 °F) | |
Equipment protection level Dc | ||
CE marking | [*PD-Z02586A*] | |
Special conditions | ||
Maximum heating (Temperature rise) | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. The maximum surface temperature at maximum ambient temperature is given in the Ex identification of the apparatus. |
|
at UBmax=60 V, IL=200 mA | 19 K | |
at UBmax=60 V, IL=100 mA | 15 K | |
at UBmax=30 V, IL=200 mA | 15 K | |
Equipment protection level Dc (tc) | ||
CE marking | [*PD-Z02586A*] | |
General | The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
Special conditions | ||
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. |
|
at UBmax=60 V, IL=200 mA | 50 °C (122 °F) | |
at UBmax=60 V, IL=100 mA | 54 °C (129.2 °F) | |
at UBmax=30 V, IL=200 mA | 54 °C (129.2 °F) | |
Equipment protection level Dc (tD) | ||
General | The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! |
|
Special conditions | ||
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. |
|
at UBmax=60 V, IL=200 mA | 50 °C (122 °F) | |
at UBmax=60 V, IL=100 mA | 54 °C (129.2 °F) | |
at UBmax=30 V, IL=200 mA | 54 °C (129.2 °F) | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 3G; 3D |