(!) Производство этого продукта прекращено, изделие имеет замену. Перейти к странице изделия-замены. NJ10-30GM50-E2-5M-3G-3D

Технические данные PDF

Краткое описание: технические характеристики  NJ10-30GM50-E2-3G-3D- xx3Gxx3D

General specifications
Switching function Normally open (NO)
Output type PNP
Rated operating distance 10 mm
Installation flush
Output polarity DC
Assured operating distance 0 ... 8.1 mm
Actual operating distance 9 ... 11 mm typ. 10 mm
Reduction factor rAl 0.32
Reduction factor rCu 0.32
Reduction factor r304 0.72
Reduction factor rBrass 0.43
Nominal ratings
Operating voltage 10 ... 60 V
Switching frequency 0 ... 650 Hz
Hysteresis 1 ... 15 typ. 5 %
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Voltage drop ≤ 2.8 V
Voltage drop at IL
Voltage drop IL = 10 mA, switching element on 0.9 ... 2.4 V typ. 1.7 V
Voltage drop IL = 20 mA, switching element on 0.9 ... 2.4 V typ. 1.7 V
Voltage drop IL = 50 mA, switching element on 0.9 ... 2.5 V typ. 1.7 V
Voltage drop IL = 100 mA, switching element on 1 ... 2.6 V typ. 1.8 V
Voltage drop IL = 200 mA, switching element on 1.2 ... 2.8 V typ. 2 V
Operating current 0 ... 200 mA
Off-state current 0 ... 0.5 mA typ. 0.01 mA
No-load supply current ≤ 9 mA
Switching state indicator LED, yellow
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval Certified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection type cable PVC 5 m
Core cross-section 0.75 mm2
Housing material Stainless steel 1.4305 / AISI 303
Sensing face PBT
Housing diameter 30 mm
Degree of protection IP67
Cable
Bending radius > 10 x cable diameter
Equipment protection level Gc (nA)
Certificate of Compliance PF 15CERT3754 X
Special conditions
Protection against transients Ensure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded.
Equipment protection level Dc (tc)
Instruction Manual electrical apparatus for hazardous areas
Device category 3D for use in hazardous areas with combustible dust
Certificate of Compliance PF 15CERT3774 X
CE marking [*PD-Z02586A*]
ATEX marking Ex-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
Standards EN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
General The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Maximum operating current IL The maximum permissible load current must be restricted to the values given in the following list.
High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmax dependant of the load current IL and the max. operating voltage UBmax
Information can be taken from the following list.
at UBmax=60 V, IL=200 mA 53 °C (127.4 °F)
at UBmax=30 V, IL=100 mA 59 °C (138.2 °F)
Protection from mechanical danger The sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cable The connection cable must be prevented from being subjected to tension and torsional loading.
Electrostatic charge Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Use in the hazardous area see instruction manuals
Category 3G; 3D
Оформить заказ на NJ10-30GM50-E2-3G-3D- xx3Gxx3D вы можете в компании compeq-pepperl отправив заявку по почте, а также по телефону или в офисе компании.
Вам может понравиться