Технические данные PDF

Краткое описание: технические характеристики  NCB50-FP-Z2-P1

General specifications
Switching functionNormally open/closed (NO/NC)
Output typeTwo-wire
Rated operating distance50 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 40.5 mm
Actual operating distance45 ... 55 mm typ.
Reduction factor rAl 0.4
Reduction factor rCu 0.35
Reduction factor r304 0.8
Output type2-wire
Nominal ratings
Operating voltage10 ... 60 V DC
Switching frequency0 ... 80 Hz
Hysteresis0 ... 20 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop≤ 3.8 V
Voltage drop at IL
Voltage drop IL = 20 mA, switching element on2.7 ... 4.9 V
Operating current2 ... 200 mA
Lowest operating current2 mA
Off-state current≤ 0.6 mA
Time delay before availability≤ 300 ms
Switching state indicatorLED, yellow
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 %
Core cross-sectionup to 2.5 mm2
Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Housing materialPBT
Sensing facePBT
Housing basePBT
Degree of protectionIP68
Protection classII
Оформить заказ на NCB50-FP-Z2-P1 вы можете в компании compeq-pepperl отправив заявку по почте, а также по телефону или в офисе компании.