NCB50-FP-E2-P1-V1-3G- xx3Gxx3D
Артикул: 129867
Inductive sensor
12 090 Р
Производитель:
PEPPERL+FUCHS
Поделиться:
Производитель: PEPPERL+FUCHS
Краткое описание: технические характеристики NCB50-FP-E2-P1-V1-3G- xx3Gxx3D
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 50 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 40.5 mm | |
Reduction factor rAl | 0.38 | |
Reduction factor rCu | 0.35 | |
Reduction factor r304 | 0.83 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 60 V DC | |
Switching frequency | 0 ... 80 Hz | |
Hysteresis | typ. 3 % | |
Reverse polarity protection | reverse polarity protected | |
Voltage drop | ≤ 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA | |
No-load supply current | ≤ 20 mA | |
Time delay before availability | ≤ 30 ms | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 960 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
|
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector plug M12 x 1 , 4-pin | |
Housing material | PBT | |
Sensing face | PBT | |
Housing base | PBT | |
Degree of protection | IP67 | |
Equipment protection level Gc (nA) | ||
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3G Ex nA IIC T6 X | |
Standards | EN 60079-0:2006, EN 60079-15:2005 Ignition protection category "n" Use is restricted to the following stated conditions |
|
Special conditions | ||
Maximum operating current IL | The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. | |
Maximum operating voltage UBmax | The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible. | |
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. |
|
at UBmax=60 V, IL=200 mA | 44 °C (111.2 °F) | |
at UBmax=60 V, IL=100 mA | 45 °C (113 °F) | |
at UBmax=60 V, IL=25 mA | 47 °C (116.6 °F) | |
at UBmax=30 V, IL=200 mA | 50 °C (122 °F) | |
at UBmax=30 V, IL=100 mA | 53 °C (127.4 °F) | |
at UBmax=30 V, IL=50 mA | 56 °C (132.8 °F) | |
Equipment protection level Dc | ||
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3D IP67 T 95 °C (203 °F) X | |
Standards | EN 50281-1-1 Protection via housing Use is restricted to the following stated conditions |
|
Special conditions | ||
Maximum heating (Temperature rise) | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. The maximum surface temperature at maximum ambient temperature is given in the Ex identification of the apparatus. |
|
at UBmax=60 V, IL=200 mA | 25 K | |
at UBmax=60 V, IL=100 mA | 24 K | |
at UBmax=60 V, IL=25 mA | 22 K | |
at UBmax=30 V, IL=200 mA | 19 K | |
at UBmax=30 V, IL=100 mA | 16 K | |
at UBmax=30 V, IL=50 mA | 14 K | |
Equipment protection level Dc (tD) | ||
General | The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! |
|
Special conditions | ||
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. |
|
at UBmax=60 V, IL=200 mA | 44 °C (111.2 °F) | |
at UBmax=60 V, IL=100 mA | 45 °C (113 °F) | |
at UBmax=60 V, IL=25 mA | 47 °C (116.6 °F) | |
at UBmax=30 V, IL=200 mA | 50 °C (122 °F) | |
at UBmax=30 V, IL=100 mA | 53 °C (127.4 °F) | |
at UBmax=30 V, IL=50 mA | 56 °C (132.8 °F) | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 3G; 3D |