Технические данные PDF

Краткое описание: технические характеристики  NBB2-12GM60-WS

General specifications
Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance2 mm
Installationflush
Output polarityAC
Assured operating distance0 ... 1.62 mm
Reduction factor rAl 0.5
Reduction factor rCu 0.4
Reduction factor r304 0.8
Nominal ratings
Operating voltage20 ... 150 V
Switching frequency0 ... 25 Hz
Hysteresis3 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Voltage drop≤ 5 V
Momentary current
(20 ms, 0.1 Hz)
0 ... 1700 mA
Operating current5 ... 200 mA
Off-state current0 ... 1.7 mA typ.
Operating voltage indicatorLED, green
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1592 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Cable diameter4.6 mm
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter18 mm
Degree of protectionIP67
Mass125 g
NoteIn the temperature range below 0 °C, permissible operating voltage Ub 80...150 V
Safety fuse ≤ 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1
Recommendation: after a short circuit, check that the device is functioning correctly.
General information
Scope of delivery2 self locking nuts in scope of delivery
Оформить заказ на NBB2-12GM60-WS вы можете в компании compeq-pepperl отправив заявку по почте, а также по телефону или в офисе компании.