Технические данные PDF

Краткое описание: технические характеристики  SLC14-600-R/129

System components
EmitterSLC14-600-T
ReceiverSLC14-600-R/129
General specifications
Effective detection range0.2 ... 5 m
Light sourceIRED
Light typemodulated infrared light
Safety type according to IEC/EN 614964
Protection field height600 mm
Number of beams64
Operating modeStartup/restart disable preset
with Relay monitor (preset)
Optical resolution14 mm
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd2.42 E-8
Indicators/operating means
Diagnostics indicator7-segment display in receiver
Function indicatorin receiver:
LED red: OSSD off
LED green: OSSD on
LED yellow: Protected area free, system start-ready
Pre-fault indicatorLED orange
Electrical specifications
Operating voltage24 V DC (-30 %/+25 %)
Input
Function inputStart release
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP, max. 100 mA for start readiness
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Conformity
Functional safetyISO 13849-1
Product standardEN 61496-1 ; IEC 61496-2
Mechanical specifications
Degree of protectionIP67
ConnectionEmitter: terminal compartment with screw terminals, lead cross-section max. 1.5 mm2
Receiver: terminal compartment with screw terminals, lead cross-section max. 1.5 mm2
Оформить заказ на SLC14-600-R/129 вы можете в компании compeq-pepperl отправив заявку по почте, а также по телефону или в офисе компании.