Краткое описание: технические характеристики  ECA10TL-10ANP-U01BD:X3

Описание оборудования
Cable pull rotary encoder with analog interface and push buttons
General specifications
Detection typemagnetic sampling
Device typeTarget line with analog interface
Measuring range3000 ... 10000 mm
Construction type80 mm, 130 mm, 190 mm
ResolutionCable pull:
80 mm design: 0,028 mm
130 mm design: 0,047 mm
190 mm design: 0,068 mm
Encoder:
17 bit (13 bit/revolution)
Electrical specifications
Operating voltage8 ... 32 V DC
Current consumptiontyp. 15 mA (with voltage output)
typ. 20 mA (with current output)
Input 1
Input typelower limit of measurement range
Signal voltage
High8 ... 32 V DC
Signal durationmin. 1 s
Input 2
Input typeupper limit of measurement range
Signal voltage
High8 ... 32 V DC
Signal durationmin. 1 s
Analog output
Output typeanalog voltage output or analog current output
Default settingrising ramp at ccw rotation
Linearity error≤ 0.15 %
Connection
ConnectorM12 connector, 5 pin
Cable∅6 mm, 4 x 2 x 0.14 mm2, 1 m
Standard conformity
Degree of protectionacc. DIN EN 60529
Connection sidecable models: IP54
connector models: IP65
Cable pull: IP50
Climatic testingDIN EN 60068-2-3, no moisture condensation
Emitted interferenceEN 61000-6-4:2007
Noise immunityEN 61000-6-2:2005
Ambient conditions
Ambient temperature-30 ... 70 °C (-22 ... 158 °F)
Operating temperaturecable, flexing: -5 ... 70 °C (23 ... 158 °F)
cable, fixed: -30 ... 70 °C (-22 ... 158 °F)
connector models: -30 ... 70 °C (-22 ... 158 °F)
Storage temperature-30 ... 70 °C (-22 ... 158 °F)
Relative humidity98 % , no moisture condensation
Mechanical specifications
Rope diameter0.55 mm
Material
Housingnickel-plated steel
Cable pulldesign 80/130 : Luranyl® or Lexan 920
design 190 : ABS-GF17
FlangeAluminum
RopeStainless steel 1.4401/316
Life spanup to 106 Cycles
купить ITEMECA10TL-10ANP-U01BD:X3 NOCITY