Технические данные PDF

Краткое описание: технические характеристики  RHI90O-YYAYYR61T-02048

General specifications
Pulse count2048
UL File NumberE223176
Functional safety related parameters
MTTFd140 a
Mission Time (TM)20 a
L1050 E+9 at 1750 rpm
Diagnostic Coverage (DC)0 %
Electrical specifications
Operating voltage10 ... 30 V DC
No-load supply currentmax. 70 mA
Output
Output typeHTL, incremental ( Push-pull (4 in 1) outputs )
Voltage drop< 2.5 V
Load currentmax. per channel 40 mA , short-circuit protected, reverse polarity protected
Output frequencymax. 120 kHz
Rise time980 ns
De-energized delay980 ns
Connection
Connectortype 9416L (M23), 12-pin
Standard conformity
Degree of protectionDIN EN 60529, IP65
Climatic testing
Static climatic testingDIN EN 60068-2-3 40 °C, 93 % rel. humidity, no condensation
Cyclic climatic testingDIN EN 60068-2-30 55 °C, 6 cycles
Salt spray testDIN EN 60068-2-52 , 672 h
Emitted interferenceEN 61000-6-4:2007/A1:2011
Noise immunityEN 61000-6-2:2005
Shock resistance400 g, 3.5 ms
Vibration resistance30 g, 10...2000 Hz
Oscillation with broad band noiseDIN EN 60068-2-64 5 ... 500 Hz, 1.9 gRMS
Free fall testingDIN EN 60068-2-32 unpacked: 1 m, packed: 1.5 m
Approvals and certificates
UL approvalcULus Listed, General Purpose, Class 2 Power Source
Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)
Ambient conditions
Operating temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Isolation bushing16 mm , PPS-GF40
Material
Housingaluminium, salt water resitant
Flangealuminium, salt water resitant
ShaftHigh grade stainless steel
Massapprox. 600 g
Rotational speedmax. 3000 min -1
Starting torque≤ 6 Ncm
Shaft load
Radial offsetmax. 0.04 mm