Технические данные PDF

Краткое описание: технические характеристики  14-14366-1024-10M

General specifications
Detection typephotoelectric sampling
Pulse countmax. 5000
Electrical specifications
Operating voltage5 V DC ± 5 %
No-load supply currentmax. 150 mA
Output
Output typeRS 422, incremental
Load currentmax. per channel 20 mA , conditionally short-circuit proof
Output frequencymax. 100 kHz
Rise time100 ns
De-energized delay100 ns
Connection
Cable∅11.2 mm, 9-core, 2 m
Standard conformity
Degree of protectionDIN EN 60529, IP66
Emitted interferenceEN 61000-6-4:2007/A1:2011
Noise immunityEN 61000-6-2:2005
Ambient conditions
Operating temperature
Gas Ex-area-40 ... 55 °C (-40 ... 131 °F)
Dust Ex-area-30 ... 55 °C (-22 ... 131 °F)
Storage temperature
Gas Ex-area-40 ... 70 °C (-40 ... 158 °F)
Dust Ex-area-30 ... 70 °C (-22 ... 158 °F)
Mechanical specifications
Material
Housing3.1645 aluminum
Flange3.1645 aluminum
ShaftStainless steel 1.4305 / AISI 303
Massapprox. 3000 g
Rotational speedmax. 6000 min -1
Moment of inertia400 gcm2
Starting torque< 5 Ncm
Shaft load
Axial60 N
Radial80 N
Data for application in connection with hazardous areas
EU-Type Examination CertificateZELM 02 ATEX 0078 X
MarkingEx-Hexagon II 2G Ex db IIC T6 Gb
Ex-Hexagon II 2D Ex tb IIIC T80°C Db
Directive conformity
Directive 94/9/ECEN 60079-0:2012+A11:2013 EN 60079-1:2014 EN 60079-31:2014
купить ITEM14-14366-1024-10M NOCITY